Coriolis mass flowmeter

The Coriolis force mass flowmeter is an advanced high precision mass flow meter. Because of its excellent performance, it has high measurement accuracy, low requirement for fluid state and small pressure loss. The mass flow rate, volume flow rate, density and temperature of the measured liquid or slurry can be obtained directly by instruments of various specifications without manual calculation or estimation. ...
Hotline: 182-2103-2874

Product introduction

Cx-cmfi Coriolis mass flowmeter
?


Overview
Coriolis force mass flowmeter is an advanced high precision mass flow meter. Because of its excellent performance, it has high measurement accuracy, low requirement for fluid state and small pressure loss. The mass flow rate, volume flow rate, density and temperature of the measured liquid or slurry can be obtained directly by instruments of various specifications without manual calculation or estimation.
It can show excellent performance even in harsh working environment. There are no moving parts inside, no complicated installation and no strict requirements for working conditions. Each sensor is made of stainless steel. The output of the transmitter can meet your needs.

measuring principle
The structure of the mass flowmeter is a double elbow structure, and its measurement principle is to detect the mass flow in the pipeline by measuring the Coriolis force acting on the double elbow.
When two conditions are satisfied: (1) the double elbow vibrates at a certain frequency; (2) when there is fluid flow in the pipe, a new force, Coriolis force, is generated by the combination of pipe vibration and fluid flow. This force produces torque on the elbow, which makes the bending pipe symmetrical and its center line twist. The electrical signal is detected by displacement sensors on both sides of the elbow, and then the electrical signal is processed to obtain the mass flow directly.

Product technical parameters
Technical index parameter table (Table 1)
Indicator name technical parameter
Mass flow measurement accuracy ± [0.2% + (zero stability / instantaneous mass flow rate × 100%)]
Repeatability of mass flow measurement ± (1 / 2) × [0.2% + (zero stability / instantaneous mass flow rate × 100%)]
Density measurement range 0.2?g/cm3~3.5g/cm3
Density measurement accuracy ±0.002g/cm3
Temperature measurement range -60℃~+200℃
Temperature measurement accuracy ±1℃
Current output 4mA~20mA
Frequency output 0Hz~10kHz
Contact capacity of batch control relay 24V/0.1A
Contact form of batch control relay Normally open (it can be changed to normally closed when the user orders)
?
Table of working environment parameters (Table 2)

Name Parameters
Fluid medium temperature -40℃~+200℃
Working environment temperature 0℃~+40℃
Working environment humidity ≤ 90% RH, non condensing
atmospheric pressure 86kPa~106kPa
Transmitter power supply requirements Intrinsically safe power supply voltage: AC (220 ± 10%) V, (50 ± 5%) Hz
Composite power supply voltage: (24 ± 10%) V
Overall power <?15W

Specifications, models and basic parameters (Table 3)
Specification and model Nominal diameter
(mm)
Flow range
(t/h)
Measurement range
(t/h)
Working pressure upper limit
(MPa)
Zero stability
(t)
Velocity factor
(h?m/t?s)
DN1 one 0~0.04 0.004~0.04 thirty zero point zero zero zero zero zero eight three hundred and fifty-three point seven
DN3 three 0~0.35 0.035~0.35 thirty zero point zero zero zero zero six seven thirty-nine point three
DN6 six 0~0.7 0.07~0.7 thirty zero point zero zero zero one six nineteen point six five
DN10 ten 0~1.2 0.12~1.2 thirty zero point zero zero zero two four point nine one two
DN15 fifteen 0~6.4 0.64~6.4 four zero point zero zero one one two point one eight three
DN25 twenty-five 0~16 1.6~16 four zero point zero zero two zero point nine zero two
DN40 forty 0~40 4~40 four zero point zero zero three zero point three three four
DN50 fifty 0~65 6.5~65 four zero point zero zero six zero point one nine seven
DN80 eighty 0~160 16~160 two point five zero point zero one zero point zero eight seven three
DN100 one hundred 0~250 25~250 two point five zero point zero one five zero point zero five four four

4. Product structure
According to the nominal diameter of the pipeline, the product specifications can be divided into 10 types: DN 1, DN 3, n n 6, n 10, n 15, n 25, n n 40, n 50, n n 80, N 100 (unit: mm).
 Product display of Coriolis mass flowmeter ?????? Product display of Coriolis mass flowmeter (2)
Fig. 1 sensor (primary table)
 Sensor Figure 1  Sensor 2
Type II transducer and secondary transducer

Installation dimensions (Table 5)
model Nominal diameter DN (mm) Dimensions and related dimensions (mm) Number and diameter of flange connection hole or threaded joint Weight (kg)
A B C D
DN1 one one hundred and ninety-three two hundred seventy-five (234) M12 × 1.5 internal thread four
DN3 three one hundred and ninety-three two hundred and twenty-five seventy-five (288) M15.1 × 1 four point five
DN6 six two hundred and twenty-one two hundred and eighty-two eighty-seven (370) M16 × 1.5 internal thread seven point five
DN10 ten two hundred and fifty-six two hundred and ninety-one seventy-three (370) M20 × 1.5 internal thread nine
DN15 fifteen three hundred and seventy-nine five hundred and three ninety φ65 4-φ14 fifteen
DN25 twenty-five four hundred and seventy-three five hundred and forty-eight ninety-six φ85 4-φ14 eighteen point five
DN40 forty five hundred and twenty-two six hundred and sixteen one hundred and sixteen Φ110 4-φ18 twenty-five point five
DN50 fifty five hundred and ninety-seven six hundred and seventy-six one hundred and thirty-seven φ125 4-φ18 thirty-five
DN80 eighty six hundred and fifty eight hundred and thirty-seven one hundred and seventy-five φ160 8-φ18 fifty-three point five
DN100 one hundred seven hundred and fourteen nine hundred and thirty-four one hundred and ninety-eight φ190 8-φ22 seventy

Production flow chart
 Flow chart of Coriolis mass flowmeter

Installation guide diagram
 Coriolis installation guide

After sales service commitment of Coriolis mass flowmeter:

Pre sales and in-sales services: at this stage, we will be responsible for technical Q & A for customers, select models according to customers' technical requirements and site conditions, and determine flowmeter models for final customers.

after-sale service:
1. On site service:
Our company can send technical engineers to be responsible for the on-site installation, commissioning and technical training of instruments. The training contents include how to install, debug, set up, operate and maintain (the contract amount does not include this fee, which needs to be charged separately). The repair and replacement within one year after the products are sold, and the life-long maintenance (only the cost fee will be charged after the warranty period).
2. Other commitments
1) After the products are sold, the freight to the address designated by the buyer shall be borne by the buyer.
2) The warranty period is one year. During this period, in case of equipment failure caused by our company's manufacturing reasons (except for improper use or artificial damage by the demander), our company will respond as soon as possible after receiving the formal written or telephone call from the user, take solutions within 2 hours, arrive at the site within 24 hours for service, or send the required replacement parts by express mail until the problem is solved Question. Our company is well stocked, each model has 30-50 sets of semi-finished products for stock. We promise that if there are product quality problems, we can replace the new meter free of charge within one year.
3) Our product software technology update, users can enjoy free upgrade.
4) After the products are sold, the service personnel often investigate, collect and record the feedback information of customers through telephone, letter, visit and other forms, properly handle the customers' opinions and understand the customers' needs, so as to obtain the continuous satisfaction of customers.
3. Quality commitment
Ensure that the equipment is manufactured in accordance with the user's technical requirements and quality requirements (according to ISO9000 quality certification system), eliminate quality accidents, ensure equipment quality, and meet the technical requirements.
Shanghai Cixi Coriolis mass flowmeter Welcome the new year, the end of the year, new and old customers to buy this product enjoy 10% discount! For details, please call 021-57632436