Precession Vortex Flowmeter

Cx-vpfm-luxb intelligent gas Precession Vortex Flowmeter working principle: the flow profile of the flow sensor is similar to the profile of Venturi tube. A set of spiral guide vanes are placed at the inlet side. When the fluid enters the flow sensor, the guide vane forces the fluid to produce violent vortex flow. When the fluid enters the diffusion section, the vortex flow is affected by the backflow, and begins to make a second rotation, forming Tuo
Hotline: 182-2103-2874

Product introduction

Cx-vpfm-luxb intelligent gas Precession Vortex Flowmeter
?

 Precession Vortex Flowmeter gas flowmeter methane flowmeter nitrogen flowmeter gas flowmeter hydrogen flowmeter ?
?
working principle:

The flow profile of the flow sensor is similar to the profile of Venturi tube. A set of spiral guide vanes are placed at the inlet side. When the fluid enters the flow sensor, the guide vane forces the fluid to produce violent vortex flow. When the fluid enters the diffusion section, the vortex flow is affected by the backflow, and begins to make a second rotation, forming a gyroscopic vortex precession phenomenon. The precession frequency is directly proportional to the flow rate and is not affected by the physical properties and density of the fluid. The signal is amplified, filtered and shaped by a preamplifier and converted into a pulse signal proportional to the flow rate, and then sent to the microprocessor together with the detection signals such as temperature and pressure for integration processing. Finally, the measurement results (instantaneous flow, cumulative flow, temperature and pressure data) are displayed on the LCD screen.
?
Flow meter structure: ??????????????????????????????????????????????
1. Vortex generator
It is a spiral blade with a certain angle, which is fixed in the front of the shell contraction section, forcing the fluid to produce strong vortex flow.
2. Shell
It can be made of stainless steel and stainless steel according to different working conditions. ?????????
3. Intelligent flowmeter totalizer
It is composed of temperature and pressure detection analog channel, flow detection digital channel, micro processing unit, liquid crystal drive circuit and other auxiliary circuits. ???????????????
Sensor 4
PT100 platinum resistance is used as temperature sensitive element, and its resistance value is corresponding to temperature in a certain temperature range.
5. Pressure sensor
With piezoresistive diffused silicon bridge as sensing element, the bridge arm resistance will change as expected under the action of external pressure. Therefore, under the action of certain exciting current, the potential difference between the two output terminals is directly proportional to the external pressure.
Piezoelectric crystal sensor
The frequency of the expanding vortex can be detected near the throat of the shell.
Racemizer
It is fixed at the outlet section of the shell, and its function is to eliminate the vortex flow, so as to reduce the impact on the performance of downstream instruments.
?
Main technical parameters and functions:
Specifications, basic parameters and performance indexes of flowmeter
Nominal diameter
DN(mm)
Flow range
(m3/?h)
Working pressure (MPA) Accuracy class Repeatability
fifteen 1.5~12 one point six
two point five
four
six point three
ten
sixteen
twenty-five
forty-two
one
one point five
Less than 1 / 3 of the absolute value of the basic error limit
twenty 2~15
twenty-five 3.0~30
thirty-two 6.0~60
forty 7.0~70
fifty 10~130
eighty 30~400
one hundred 70~800
one hundred and twenty-five 90-1000
one hundred and fifty 190~1900
two hundred 240~3600
Standard condition: P = 101.325kpa, t = 293.15K
Service conditions:
Ambient temperature: - 30 ℃~ + 65 ℃
Relative humidity: 5% - 95%
Medium temperature: - 20 ℃~ + 80 ℃
Atmospheric pressure: 86kpa ~ 106kpa
Explosion proof sign: ExdIIBT4; ExiaIICT4
Protection grade: IP65
pressure loss
?
Working power supply:
A. External power supply: + 24 VDC ± 15%, ripple < 5%, suitable for 4 ~ 20mA output, pulse output, alarm output, RS-485, Hart, etc;
B. Internal power supply: a group of 3.6V lithium batteries (er26500), when the voltage is lower than 3.0V, under voltage indication appears.
Power consumption:
A. External power supply: < 2W;
B. Internal power supply: the average power consumption is 1MW, which can be used for more than two years.
Output mode:
1) Pulse output
2) Equivalent output
3) RS-485 communication (photoelectric isolation)
4) 4-20mA standard current signal (photoelectric isolation)
?
The actual pressure loss calculation formula of flowmeter is as follows:
 Formula of intelligent gas Precession Vortex Flowmeter ………………… (1)
Where:
Δ P1 · - actual pressure loss of flowmeter (kPa);
ρ -- density of measured medium (kg / m3)
Δ P · - pressure loss (kPa) of flowmeter when the medium is dry air, and its characteristic curve is shown in the figure below
 Wiring diagram of intelligent gas Precession Vortex Flowmeter ?
Connection port: outlet interface is M20 × 1.5 internal thread.
?
4. Selection and installation

The selection calculation formula is as follows:
?

?
In the formula: T, P and PA are the same as above, q is the volume flow rate, QN is the standard volume flow rate, and the Z / Zn values are listed in Table 2. Due to the large calculation step, the data in the table are only for reference. The data in the table are calculated according to the true relative density of natural gas GR = 0.600, and the mole fraction of nitrogen and carbon dioxide is 0.00. When the medium pressure is lower than 0.1MPa, it can be estimated as Z / Zn = 1.
?????????????????????????????????????????????????????????
?
Outline dimension and installation dimension of flowmeter
The overall dimension of the flowmeter is shown in the figure. The flowmeter adopts flange, thread, clamp and other connection methods. ?
 Design of intelligent gas Precession Vortex Flowmeter ?
Flange connection type
Nominal diameter
DN(mm)
Nominal pressure
(MPa)
Overall dimension (mm) Body material weight
(kg)
Connection mode
Body length a Height h stainless steel aluminium alloy
15/20 1.6、2.5、4.0 one hundred and sixty three hundred and sixty six Flange type
Screw type
Clamp type
6.3、10 one hundred and sixty three hundred and sixty-five ? eight
twenty-five 1.6、2.5、4.0 one hundred and eighty three hundred and sixty-seven seven
6.3、10 one hundred and eighty three hundred and seventy-eight ? ten
thirty-two 1.6、2.5、4.0 two hundred three hundred and eighty-three nine
6.3、10 two hundred four hundred and two ? twelve
forty 1.6、2.5、4.0 two hundred three hundred and eighty-three nine
6.3、10 two hundred four hundred and two ? twelve
fifty 1.6、2.5、4.0 two hundred and thirty four hundred and three eleven
6.3、10 two hundred and thirty four hundred and twenty-one ? fourteen
eighty one point six three hundred and thirty four hundred and thirty-eight eleven
2.5、4.0 three hundred and thirty four hundred and thirty-eight ? eighteen
6.3、10 three hundred and thirty four hundred and forty-six ? twenty-one
one hundred one point six four hundred and ten four hundred and sixty-eight fourteen
2.5、4.0 four hundred and ten four hundred and seventy-five ? eighteen
6.3、10 four hundred and ten four hundred and eighty-three ? thirty-three
one hundred and fifty one five hundred and eighty-five five hundred and forty-two twenty-one Flange type
1.6、2.5 five hundred and eighty-five five hundred and forty-nine ? fifty-two
4.0、6.3、10 five hundred and eighty-five five hundred and seventy-two ? seventy-two
two hundred one seven hundred six hundred and eighteen forty-one
1.6、2.5 seven hundred six hundred and twenty-six ? one hundred and seventeen
4.0、6.3、10 seven hundred six hundred and thirty-four ? one hundred and twenty-seven
Note: high pressure gauges need to be customized, and the common ones are 10MPa, 16MPa, 20MPa, 25MPa and 42MPa.
?
 Pipeline diagram of intelligent gas Precession Vortex Flowmeter